Call 800-292-1672
Print this Page Send this Page
  1. pin-int

Sick 1054397

Sick 1054397 RFU630 Long Range RFID Write/Read Device with Integrated Antenna; 5m Scanning Range, 860 to 960 MHz UHF Frequency Band

  • MPN: 1054397
  • AHPPN: 1054397
  • Min. Order Qty: 1
  • Quantity Interval: 1
* Sell and Ship Exclusively to Kentucky, Alabama, Mississippi
  • Qty:

Sick RFU630 Long Range RFID Write/Read Device with Integrated Antenna; Version: Long Range; Radio Approval: USA (FCC Part 15.247), Canada (RSS-210), México (NOM-121); Frequency Band: UHF (860 MHz to 960 MHz); RFID Standard: EPCglobal UHF Class 1 Generation 2, ISO/IEC 18000-6 C; Modulation: PR-ASK, DSB-ASK; Mission Time: 14 Years; Scanning Range: 5m (Typical); Antenna Type: Integrated; Control Type: 2 Buttons (Choose & Start/Stop Functions); Service Functions: Parameter Cloning with Integrated MicroSD Memory Card Slot or Externally Via CMC Module in CDB620; Optical Interface: 8 LEDs, One of Them Multi-Colored (Function Configurable via SOPAS ET, Alternatively Controlling with SW Commands, Status Displays); Acoustic Indicators: Beeper/Buzzer (Can be Switched Off, Can be Allocated as a Result Indication Function); Connection Type: 1 x M12, 17-Pin male Connector, 1 x M12, 4-Pin Ethernet female Connector; Operating Voltage: 18 to 30 VDC; Operating Frequency: 902.75 MHz to 927.25 MHz; Power Consumption: < 20 W (with Switching Outputs not Connected & Full Transmit Power); Output Power: 4 W (EIRP, With Integrated Antenna, Alternatively 30 dBm at the External Antenna Port, Output Power Adjustable); Switching Input: 4 ("Sensor 1", "Sensor 2", 2 Inputs Via Optional Parameter Storage CMC600 in CDB620/CDM420); Switching Output: 4 (2 Results, 2 Outputs Via Optional Parameter Storage CMC600 in CDB620/CDM420); Enclosure Rating: IP67; Protection Class: III; Configuration Software: SOPAS ET; Permissible Relative Humidity: ± 90 % (Non-Condensing); Electromagnetic Compatibility: EN 61000-6-4 (2007-09)/EN 61000-6-2 (2009-05); Vibration Resistance: EN 60068-2-6 (2008-02); Shock Resistance: EN 60068-2-27 (2009-05); Housing Material: Aluminum Die-Cast; Housing Color: Blue, Black, Silver; Dimension: 239 mm x 239 mm x 64 mm; Operating Temperature: -25 to 60°C; Storage Temperature: -30 to 70°C; Weight: 3.5 kg

Version      :      Long Range
Radio Approval      :      USA (FCC Part 15.247), Canada (RSS-210), México (NOM-121)
Frequency Band      :      UHF (860 MHz to 960 MHz)
RFID Standard      :      EPCglobal UHF Class 1 Generation 2, ISO/IEC 18000-6 C
Modulation      :      PR-ASK, DSB-ASK
Mission Time      :      14 Years
Scanning Range      :      5m (Typical)
Antenna Type      :      Integrated
Control Type      :      2 Buttons (Choose & Start/Stop Functions)
Service Functions      :      Parameter Cloning with Integrated MicroSD Memory Card Slot or Externally Via CMC Module in CDB620
Optical Interface      :      8 LEDs, One of Them Multi-Colored (Function Configurable via SOPAS ET, Alternatively Controlling with SW Commands, Status Displays)
Acoustic Indicators      :      Beeper/Buzzer (Can be Switched Off, Can be Allocated as a Result Indication Function)
Connection Type      :      1 x M12, 17-Pin male Connector, 1 x M12, 4-Pin Ethernet female Connector
Operating Voltage      :      18 to 30 VDC
Operating Frequency      :      902.75 MHz to 927.25 MHz
Power Consumption      :      < 20 W (with Switching Outputs not Connected & Full Transmit Power)
Output Power      :      4 W (EIRP, With Integrated Antenna, Alternatively 30 dBm at the External Antenna Port, Output Power Adjustable)
Switching Input      :      4 ("Sensor 1", "Sensor 2", 2 Inputs Via Optional Parameter Storage CMC600 in CDB620/CDM420)
Switching Output      :      4 (2 Results, 2 Outputs Via Optional Parameter Storage CMC600 in CDB620/CDM420)
Enclosure Rating      :      IP67
Protection Class      :      III
Configuration Software      :      SOPAS ET
Permissible Relative Humidity      :      ± 90 % (Non-Condensing)
Electromagnetic Compatibility      :      EN 61000-6-4 (2007-09)/EN 61000-6-2 (2009-05)
Vibration Resistance      :      EN 60068-2-6 (2008-02)
Shock Resistance      :      EN 60068-2-27 (2009-05)
Housing Material      :      Aluminum Die-Cast
Housing Color      :      Blue, Black, Silver
Dimension      :      239 mm x 239 mm x 64 mm
Operating Temperature      :      -25 to 60°C
Storage Temperature      :      -30 to 70°C
Weight      :      3.5 kg

The ability to network sensors is becoming particularly important in the light of demands for cost-effective solutions. SICK has the tools to meet this challenge: Through the 4Dpro platform, it offers a product portfolio that is perfect for fieldbus systems. It gives you the freedom to select the identification and vision technology you require, and enables flexible integration into numerous fieldbus technologies with very little cabling work. The function blocks, available free of charge, keep the amount of work required for integration and programming in the PLC to a minimum. The graphics below show how the 4Dpro sensors can be integrated.

  • UHF RFID Read/write unit for industrial applications
  • With or without integrated antenna, depending on the type (up to four external antennas can be connected)
  • Standard-compliant transponder interface (ISO/IEC 18000-6C/EPC G2C1)
  • Supports common industrial data interfaces and fieldbuses
  • MicroSD Memory card for device parameter cloning
  • Several diagnostic and service options available
  • Other functions like cloning function (microSD memory card or system), diagnosis, updatable firmware, freely programmable data output format, heartbeat, triggering, SICK AppSpace functionalities can be enabled with the SD card accessory SDK6U-P00100
  • Ethernet interface TCP/IP, Host & AUX function & data transmission rate of 10/100 MBit/s
  • PROFINET Single port, PROFINET dual port (optional via external connection module CDF600-2) & data transmission rate of 10/100 MBit/s
  • EtherCAT Type of fieldbus integration optional over external fieldbus module CDF600
  • Serial Interface: RS-232, RS-422, RS-485, host & AUX function & data transmission rate of 0.3 to 115.2 kBaud, AUX: 57.6 kBaud (RS-232)
  • CAN Interface: CSN (SICK CAN Sensor Network), host function
  • PROFIBUS DP type of fieldbus integration optional over external fieldbus module CDF600-2
  • DeviceNet type of fieldbus integration Optional available externally
  • USB 2.0 Port, AUX function

Standard/Approvals:FC Listed, 4Dpro

Availability By Branch

Branch Name Available

Write Review

Atleast 50 Characters. You can Express Upto 1000 Characters
© 2020 Air Hydro Power Inc. All rights reserved

LoginSign Up

Forgot your Password?

Loading

Add Item To Add Item To